SikaBond® T-45
SikaBond® T-45 is a 1-component, semi-elastic, wood flooring adhesive with good workability.
- Adhesive can be sanded
- Floor can be walked on / sanded after 24 / 48 hours
- Semi-elastic
- Suitable for use with underfloor heating
- Good workability
- Especially suitable for woods without tongued and grooved connections
- Especially suitable for engineered wood floors
Usage
SikaBond® T-45 is designed for full surface bonding of a wide variety of wood floor types and is especially suitable for wood floors types without tongued and grooved connections (e. g lam parquet, industrial and mosaic parquet). SikaBond® T-45 is also very suitable for engineered wood floors (strips and planks).Advantages
- Adhesive can be sanded
- Floor can be walked on / sanded after 24 / 48 hours
- Semi-elastic
- Suitable for use with underfloor heating
- Good workability
- Especially suitable for woods without tongued and grooved connections
- Especially suitable for engineered wood floors
Packaging
1800 ml foil pack, 6 foil packs per box
15 kg metal pail
Colour
Parquet brown
Product Details
Chemical Base
Polyurethane
Shelf Life
SikaBond® T-45 has a shelf life of 9 months from the date of production, if it is stored properly in undamaged, original, sealed packaging, and if the storage conditions are met.
Storage Conditions
SikaBond® T-45 shall be stored in dry conditions, protected from direct sunlight and at temperatures between +5 °C and +25 °C.
Density
1.45 kg/l approx. | (ISO 1183-1) |
Shore A Hardness
60 approx. (after 28 days) | (ISO 868) |
Tensile Strength
1.3 N/mm2 approx. | (ISO 37) |
Shear Strength
0.90 N/mm2 approx., 1 mm adhesive thickness | (ISO 17178) |
Service Temperature
+5 °C to +40 °C
Application
Sag Flow
SikaBond® T-45 spreads very easily whilst maintaining stable trowel marks.
Ambient Air Temperature
+15 °C to +35 °C
Relative Air Humidity
40% to 70%
Substrate Temperature
During laying and until SikaBond® T-45 has fully cured, the substrate and ambient temperatures shall be between +15 °C and +35 °C without and between +20 °C and +35 °C with underfloor heating.
Substrate Moisture Content
Permissible substrate moisture content without underfloor heating:
- 2.5% CM for cement screeds.
- 0.5% CM for anhydrite screeds.
- 3–12% CM for magnetite flooring (depending on the organic content).
Permissible substrate moisture content for use with underfloor heating:
- 1.8% CM for cement screeds.
- 0.3% CM for anhydrite screeds.
- 3–12% CM for magnetite flooring (depending on the organic content).
Note: For all moisture contents, the quality of the substrates and surfaces, always follow the guidelines of the wood flooring manufacturer.
Curing Rate
4.0 mm/24 hours approx. (23 °C / 50% r.h.)
Skin Time / Laying Time
90 minutes approx. (23 °C / 50% r.h.)
Consumption
Full Surface Bonding:
- 600−800 g/m2 with notched trowel B3 (TKB Germany) e.g. for lam parquet, mosaic parquet and industrial parquet.
- 750−1000 g/m2 with notched trowel B6 (TKB Germany) or SC+ MB (US Standard) e.g. for engineered wood strips and planks, lam and mosaic parquet.
- 900−1100 g/m2 with notched trowel B11 (TKB Germany) or P5 (US Standard) e.g. solid wood, engineered long-strips and panels, industrial parquet, other residential wood floors and paving, and chipboard.
Full Surface Bonding with SikaBond® Dispenser-1800 /-3600 /-5400:
- For full surface bonding with the SikaBond® Dispenser please refer to the Method Statements of the SikaBond® Dispenser series.
For bonding long or wide boards, or when working on uneven substrates, it may be necessary to use a notched trowel with bigger notches to ensure that a sufficient amount of SikaBond® T-45 is applied to provide a uniform adhesive surface and prevent hollow sections i.e. without full surface bond.
For substrates primed with Sika® Primer MR Fast or Sika® Primer MB, the consumption of SikaBond® T-45 may be reduced.
APPLICATION INSTRUCTIONS
For the application of SikaBond® T-45 all standard construction guidelines apply.
For further information, please refer to the Method Statement "Full Surface Bonding".
SUBSTRATE PREPARATION
- The substrate must be clean, dry, sound and homogeneous, free from oils, grease, dust and loose or friable particles. Paint, cement laitance and other poorly adhering contaminants must be removed.
- Concrete and/or cement screeds must be ground and thoroughly cleaned with an industrial vacuum.
- Anhydrite screeds, including flowable anhydrite screeds must be ground and thoroughly cleaned with an industrial vacuum shortly before bonding with the adhesive starts.
- Broadcast mastic asphalt must be primed with Sika® Primer MR Fast or Sika® Primer MB. For the instructions for use, please refer to the corresponding Product Data Sheet.
- Wood and/or gypsum boards (e.g. chipboard, plywood) must be glued and/or screwed to the substructure in order to be fixed to the substrate. For floating dry-floors, contact our Technical Service Department.
- For other substrates contact our Technical Service Department for advice and assistance.
- SikaBond® T-45 can be used without priming on cement based floors, anhydrite floors, chipboards, concrete and ceramic tiles.
- For broadcasted mastic asphalt, cement based floors with excessive moisture content and use over old adhesive residues or on weak substrates use Sika® Primer MB. For detailed instructions contact our Technical Service Department.
CLEANING OF TOOLS
Clean all tools and application equipment immediately after use with Sika® Remover-208 and/or Sika® TopClean T. Once cured, residual material can only be removed mechanically.