Sikafloor®-304 W
Water-based polyurethane matt seal coat
Sikafloor®-304 W is a 2-part water-based, very-low-VOC, polyurethane matt seal coat. It is part of the Sika Comfortfloor® flooring range.
- Water-based
- Good resistance to UV exposure
- Good yellowing resistance
- Low odour
- Low VOC emissions
- Low VOC content
- Low maintenance
Usage
The Product is used as a:- Matt seal coat for Sikafloor® systems
- The Product may only be used for interior applications.
Advantages
- Water-based
- Good resistance to UV exposure
- Good yellowing resistance
- Low odour
- Low VOC emissions
- Low VOC content
- Low maintenance
Packaging
Container Part A | 6.0 kg |
Container Part B | 1.5 kg |
Container Part A + Part B | 7.5 kg |
Refer to the current price list for available packaging variations.
Colour
Part A | white, liquid |
Part B | yellowish, liquid |
Cured appearance | matt finish |
Cured colour | Transparent |
Product Details
ENVIRONMENTAL INFORMATION
Contributes towards satisfying Indoor Environmental Quality (EQ) Credit: Low-Emitting Materials under LEED® v4
Contributes towards satisfying Indoor Environmental Quality (EQ) Credit: Low-Emitting Materials under LEED® v4
Contributes towards satisfying Materials and Resources (MR) Credit: Building product disclosure and optimization — Environmental Product Declarations under LEED® v4
Environmental Product Declaration (EPD) in accordance with EN 15804. EPD independently verified by Institut für Bauen und Umwelt e.V. (IBU)
APPROVALS / STANDARDS
CE marking and declaration of performance based on EN 13813:2002 Screed material and floor screeds — Screed material — Properties and requirements — Synthetic resin screed material
CE marking and declaration of performance based on EN 1504-2:2004 Products and systems for the protection and repair of concrete structures — Surface protection systems for concrete — Coating
Chemical Base
Water-based polyurethane
Shelf Life
Part A | 6 months from date of production |
Part B | 12 months from date of production |
Storage Conditions
The Product must be stored in original, unopened and undamaged sealed packaging in dry conditions at temperatures between +5 °C and +30 °C. Always refer to packaging.
Refer to the current Safety Data Sheet for information on safe handling and storage.
Density
Part A | 1.05 kg/l |
Part B | 1.13 kg/l |
Mixed Product | 1.07 kg/l (diluted with 5 % Water) |
Tensile Adhesion Strength
> 1.5 N/mm² (failure in concrete) | (EN 1542) |
Gloss level
85° | < 55 |
60° | < 10 |
Application
Mixing Ratio
Part A : Part B (by weight) | 80 : 20 |
Product Temperature
Maximum | +30 °C |
Minimum | +10 °C |
Ambient Air Temperature
Maximum | +30 °C |
Minimum | +10 °C |
Relative Air Humidity
Maximum | 75 % r.h. |
Dew Point
Beware of condensation. The substrate and uncured applied product must be at least +3 °C above dew point to reduce the risk of condensation on the surface of the applied product.
Substrate Temperature
Maximum | +30 °C |
Minimum | +10 °C |
Substrate Moisture Content
Refer to the individual primer Product Data Sheet.
Pot Life
+10 °C | 50 minutes |
+20 °C and 50 % r.h. | 30 minutes |
+25 °C | 20 minutes |
Consumption
0.13 kg/m² per layer (diluted with 10 % water) |
EQUIPMENT
Select the most appropriate equipment required for the project:
MIXING EQUIPMENT
Electric single paddle mixer (300 to 400 rpm)
Clean mixing containers
APPLICATION EQUIPMENT
Short-pile nylon roller
Airless spray equipment
SUBSTRATE QUALITY
Cementitious substrates must be structurally sound and of sufficient compressive strength (minimum 25 N/mm2) with a minimum tensile strength of 1.5 N/mm2.
Substrates must be clean, dry and free of contaminants such as dirt, oil, grease, coatings, laitance, surface treatments and loose friable material.
SUBSTRATE PREPARATION
IMPORTANT
Application on epoxy substrates
When applying the Product on an epoxy substrate, the floor must be sanded to secure proper adhesion.
- Sand the substrate with a 3M Brown Stripper Pad in combination with low-speed automatic scrubbers or rotary floor machines (175 to 600 rpm).
IMPORTANT
Insufficient coating due to uneven or dirty substrates
Uneven or dirty substrates cannot be covered by thin seal coats.
- Clean the substrate and adjacent areas thoroughly prior to application.
- Vacuum the substrate to remove all dirt and contamination prior to application.
MIXING
- Prior to mixing all parts, mix Part A (resin) using an electric single paddle mixer. Mix liquid until a uniform mix has been achieved.
- Add Part B (hardener) to Part A.
- IMPORTANT Avoid excessive mixing to minimise air entrainment. Mix Part A + B continuously for ~3 minutes while adding 5 % to 10 % water until a uniformly mix is achieved. Note To achieve the smoothest surface dilute using the maximum amount of water.
- Leave the Product to stand for 10 minutes before application.
APPLICATION
IMPORTANT
Strictly follow installation procedures
Strictly follow installation procedures as defined in Method Statements, application manuals and working instructions which must always be adjusted to the actual site conditions.
IMPORTANT
Protect from moisture
After application, protect the Product from damp, condensation and direct water contact for at least 24 hours.
IMPORTANT
Damaged finish due to heating with fossil fuel heaters
Fossil fuel heaters powered by gas, oil or paraffin produce large quantities of both carbon dioxide and water vapour, which may adversely affect the finish.
- For temporary heating, use only electrically powered warm air blower systems. Do not use gas, oil, paraffin or other fossil fuel heaters.
Preconditions
The substrate moisture content, relative humidity and dew point are appropriate for application. Note The floor must be divided into sections (at expansion joints or doorways when possible) that can be completed without stopping.
- Apply the mixed Product in the corners, around columns and other installations by short pile roller. Note Maintain a "wet edge" during application to achieve a seamless finish.
- Distribute the mixed Product at the correct consumption rate crosswise with a short pile nylon roller. Note Maintain a "wet edge" during application to achieve a seamless finish.
CLEANING OF TOOLS
Clean all tools and application equipment with water immediately after use. Hardened material can only be removed mechanically.